EMULEX MODEL 375 SAN STORAGE SWITCH
USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT
EMULEX CORPORATION 25
P
ART NUMBER 00041369-002 REV. B
To change the switch’s network location settings:
1. Click Switch > Configuration.
2. Enter the new value in the appropriate text box.
3. Click Submit.
The Switch Configuration page displays the updated information.
Version Information
The different software and hardware versions include:
Switch Speed
The Switch Speed setting indicates the current speed per port at which the switch is running. All ports
operate at the same speed. The default switch speed is set to 2.125 Gb/s.
To change the switch speed:
1. Click Switch > Configuration.
2. Select the desired speed.
3. Click Submit.
Blocking ARB
When two ports start a communication session, the Blocking ARB is sent to all other ports trying to
communicate with those ports until the connection is terminated. The default setting is "FF". If other
connected devices use the "FF" setting for another purpose, select another Blocking ARB value (for
example, "FB"). Under normal circumstances, this setting does not need to be modified.
Agent Up Time
The Agent Up Time field displays the duration of time that the switch has been operational. If the switch
is rebooted or power is cycled, this value is reset.
The Agent Up Time field is for display purposes and cannot be configured.
Setting Description
MAC ID A unique device address (MAC address) assigned to each switch at the
factory. This setting cannot be configured or modified.
Switch FW Version The current firmware loaded onto the switch.
Switch HW Version The hardware version of the switch. This setting cannot be configured or
modified.
SOC Version The SOC 320 version that is used in the switch. This setting cannot be
configured or modified.
MIB Version The proprietary Management Information Base version that is supported
through SNMP. This setting cannot be configured or modified.
Setting Description
1 Gb/s Set switch speed to 1.0625 Gb/s.
2 Gb/s Set switch speed to 2.125 Gb/s.