Emulex 375 User Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
EMULEX MODEL 375 SAN STORAGE SWITCH
USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT
EMULEX CORPORATION 41
P
ART NUMBER 00041369-002 REV. B
The Zone Initialization Master Port field displays the port number of the port that is currently assigned as
the master for that particular zone. The Initialization Master is responsible for starting the change
notification process in each zone.
To add ports to a zone:
1. Select the appropriate check boxes to place ports into zones.
2. Click Submit.
To activate zoning:
1. Select the Zoning Active check box near the bottom of the page.
2. Click Submit.
To remove a port from a zone:
1. Clear the appropriate check box.
2. Click Submit.
To remove all ports from a zone:
1. Click Clear at the end of the row of check boxes for the appropriate zone.
2. Click Submit.
To remove all zones:
1. Click All under the Clear Zone heading.
2. Click Submit.
Single-Switch Zoning
The simplest zoning configuration is to place each port into a single zone, so that zones are separate
from each other as shown in Figure 3-13.
In Figure 3-13, zone 1 includes ports 1, 3, and 4, while zone 2 includes ports 2 and 5. Devices on ports
1, 3, and 4 have direct access to each other and devices on ports 2 and 5 have direct access to each
other; however, devices 1, 3, and 4 are separated from devices 2 and 5.
Caution: Clearing the Zoning Active check box will deactivate all zones, which may degrade
system performance or compromise security.
Figure 3-13: Devices in a Single Zone
Page view 43