Emulex LightPulse LPe1105-M4 HBA Installation Guide Page 177

  • Download
  • Add to my manuals
  • Print
  • Page
    / 182
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 176
(CLARiiON only): Linux Navisphere Naviagent/CLI limitation with VERITAS Volume Manager v3.2 on CLARi-
iON
177
Special Instructions
(CLARiiON only): Linux Navisphere Naviagent/CLI limitation with
VERITAS Volume Manager v3.2 on CLARiiON
The Linux Navisphere Agent holds open the devices to be used by
VERITAS Volume Manager v3.2 during the initialization and
installation of the CLARiiON devices. When this occurs, the message
Devices busy or in use is reported.
The issue with the Navisphere Agent and VERITAS Volume Manager
v3.2 can occur on initialization and installation of the VxVM, as well
as on subsequent reboots.
lling and Configuring the HBA and Driver
Here is an example of the error reported during vxinstall:
If the devices were successfully partitioned during the installation,
you might also run into an issue after subsequent reboots where the
VxVM's
rootdg becomes unavailable. You will receive errors when
trying to issue VxVM commands; this is a result of the configuration
daemon (
vxconfigd) not running, and can happen if the Navisphere
host agent is running. To resolve the problem:
The Naviagent/CLI RPM may be removed from the system after it
has been used for the initial set-up and registration of the host on the
CLARiiON system.
In order to remove the RPM, stop the Naviagent service and then
remove the RPM package. For example:
/etc/init.d/naviagent stop
rpm -ev naviagentcli-6.20.0.2.59-1
Page view 176

Comments to this Manuals

No comments