Emulex LightPulse LPe1105-M4 HBA Installation Guide Page 174

  • Download
  • Add to my manuals
  • Print
  • Page
    / 182
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 173
174
EMC Host Connectivity with Emulex FC HBAs and FCoE CNAs for the Linux Environment
Special Instructions
(CLARiiON only): Linux Navisphere Agent/CLI limitation with fdisk
on CLARiiON
There is a known issue with the Linux Naviagent/CLI in which the
Naviagent does not close the sd devices before becoming a daemon
and, as a result, the devices remain open. This may cause issues when
attempting to access devices.
For example, if the Naviagent service is left running and someone
runs
fdisk to create new partitions on CLARiiON storage devices,
any attempt to make a new filesystem with
mkfs on the newly created
partition(s) will fail.
An example of a warning issued when
fdisk is run is:
WARNING: Re-reading the partition table failed with
error 16. Device or resource busy. The kernel still
uses the old table. The new table will be used at next
reboot.
If, after receiving the above warning, the user attempts to run mkfs
on a newly created filesystem, mkfs will also fail with an error similar
to the following:
mke2fs.ext2: No such device or address while trying to
determine filesystem size
This problem may be resolved in on of the ways described in detail in
the following list:
Disable the Naviagent/CLI service.
Issue a Naviagent stop command:
On RHEL, issue the command:
service naviagent stop
On SLES , issue the command:
/etc/init.d/naviagent stop
Remove the Naviagent/CLI RPM.
Rescan the SCSI bus.
Page view 173